2.3 Timer Programming
General Programming 137
[211] Dial Start Time
Description
Sets the number of milliseconds the system waits before dialling after an outside line is seized.
Selection
Time (milliseconds):
0 through 40
( 100 is the actual time)
Default
KX-TD816BX, KX-TD1232(D)BX/ML/X, KX-TDN1232 – 500 ms
KX-TD816HK, KX-TD1232HK – 1000 ms
Programming
1.
Enter
211
.
Display: 211 DIAL START
2.
Press
NEXT
.
Display example: Time: 500 msec
3.
Enter the
time
.
To change the current entry, press
CLEAR
and enter the new time.
4.
Press
STORE
.
5.
Press
END
.
Conditions
• You enter a number from
0 through 40
. The actual time is a 100 times your input.
• You cannot leave the entry empty.
Features Guide References