2.5 Outside Line Programming
222 General Programming
[451] DID Backward Group-A Signal Code (for MFC-R2)
Description
Assigns a Direct Inward Dialling (DID) call backward group-A signal code according to your
central office service.
Selection
• Code number:
01 through 15
•
Not Use / Next Digit / Complete / Congestion
Default
Code 01=Next Digit; Code 02=Not Use; Code 03=Complete; Code 04=Congestion; Code 05
to Code 15=Not Use
Programming
1.
Enter
451
.
Display: 451 FWD SIGN GPA
2.
Press
NEXT
.
Display: Code NO?
3.
Enter a
code number
.
To enter code number 01, you can also press
NEXT
.
Display example: 01:Next Digit
4.
Keep pressing
SELECT
until the desired selection is displayed.
5.
Press
STORE
.
6.
To programme another code, press
NEXT
or
PREV
, or
SELECT
and the desired
code
number
.
7.
Repeat steps 4 through 6.
8.
Press
END
.
Conditions
None
Features Guide References