2.5 Outside Line Programming
General Programming 195
[416] Reverse Circuit Assignment
Description
Enables or disables Reverse Circuit detection.
This programme is only available for the following models: KX-TD816BX/HK, KX-
TD1232DBX/ML, TDN1232.
Selection
• Outside line (CO) number:
KX-TD816 –
01 through 08,
KX-TD1232 –
01 through 24,
( =all outside lines)
•
Regular
(no detection) /
Reverse
(detection)
Default
Regular
Programming
1.
Enter
416.
Display: 416 REV. CURRENT
2.
Press
NEXT.
Display: CO Line NO?
3.
Enter an
outside line number.
To enter outside line number 01, you can also press
NEXT.
Display example: CO01:Regular
4.
Keep pressing
SELECT
until the desired selection is displayed.
5.
Press
STORE.
6.
To program another outside line, press
NEXT
or
PREV,
or
SELECT
and the desired
outside line number.
7.
Repeat steps 4 through 6.
8.
Press
END.
Conditions
To assign all outside lines to one selection, press the key in step 3. In this case, the display
shows the contents programmed for outside line 01.
Features Guide References
Reverse Circuit