2.8 Resource Programming
General Programming 277
[813] Floating Number Assignment
Description
Assigns the floating numbers for External Pagers, DISA (Direct Inward System Access)
messages, modem and extension groups. These numbers can be used in the same way extension
numbers are used for station access.
Selection
• Floating station:
Pager1 through 4 / DISA1 / DISA2 / MODEM / E-Grp 1 through 8
(Pager2 through 4 are available for the KX-TD1232 only.)
• Floating number:
2 through 4 digits
Default
Pager 1=196; Pager 2=197; Pager 3=296; Pager 4=297; DISA 1=198; DISA 2=298;
MODEM=299; E-Grp 1=191; E-Grp 2=192; E-Grp 3=193; E-Grp 4=194; E-Grp 5=291; E-
Grp 6=292; E-Grp 7=293; E-Grp 8=294
Programming
1.
Enter
813.
Display: 813 FLOATING #
2.
Press
NEXT
to programme Pager 1.
Display example: Pager1 :EXT196
To programme another floating station, keep pressing
NEXT
or
PREV
until the desired
floating station is displayed.
3.
Enter a
floating number.
To change the current entry, press
CLEAR
and enter the new floating number.
4.
Press
STORE.
5.
To programme another floating station, keep pressing
NEXT
or
PREV
until the desired
floating station is displayed.
6.
Repeat steps 3 through 5.
7.
Press
END.
Conditions
• A floating number is composed of two through four numerical digits,
0 through 9.
• The first one or two digits of the floating numbers are subject to programme
[100] Flexible Numbering, (01) through (16) 1st through 16th hundred extension blocks.
• Floating numbers and extension numbers should be different. Double entry and
incompatible entry for these numbers are invalid. Valid entry example: 10 and 11, 10 and