4.1 System Programming
342 E1 Programming
4.1 System Programming
[109] Expansion Unit Type
Description
Assigns the type of expansion units to be used in the system.
This allows the system to identify the unit in each expansion unit location.
Selection
KX-TD816
• Areas 1; 2 =
C (4 CO) / S2 (2 S0) / S6 (6 S0) / BD (4 DID-Pulse/DTMF) / MD (4 DID-
MFC) / EM (4 E&M) / E (EXT) / A (16 SLT)
KX-TD1232
•
Master / Slave
• Areas 1; 2; 3 =
C (4 CO) / S2 (2 S0) / S6 (6 S0) / PR (1 PRI) / BD (4 DID-Pulse/DTMF)
/ MD (4 DID-MFC) / EM (4 E&M) / EL (1 E1) / E1 (8 EXT1) / E2 (8 EXT2) / A1
(16 SLT1) / A2 (16 SLT2)
(Master system only: PR, EL)
Default
KX-TD816: C;E
KX-TD1232: Master and Slave – C;E1;E2
Programming
KX-TD816
1.
Enter
109.
Display: 109 EXPAND C,E1
2.
Press
NEXT.
Display example: Master:C ;E
3.
Keep pressing
SELECT
until the desired selection in Area 1 is displayed.
4.
Press to programme Area 2, if required.
5.
Keep pressing
SELECT
until the desired selection in the Area 2 is displayed.
6.
Press
STORE.
7.
Press
END.
KX-TD1232
1.
Enter
109.