EasyManua.ls Logo

ROPA Tiger 6 - Power Reduction Adblue Filling Level

ROPA Tiger 6
564 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
Diesel engine
162 / 564
6.5.3.1 Power reduction AdBlue filling level
1 When the AdBlue® level falls to 15%, the DEF control light shows YELLOW.
2 When the AdBlue® has fallen to approximately 6%, the DEF control light flashes
RED, the LIM control light also turns on.
The engine torque is reduced to 75%. The ramping down takes approximately
1 minute.
3 7 minutes after the AdBlue® tank has fallen to 6%, the DEF control light flashes
RED, and the LIM control light also flashes.
The engine torque drops to 50%. The engine speed is limited to idling speed. The
ramping down takes approximately 3 minutes.
4 If the engine is restarted when the AdBlue® level is less than 6%, the engine only
operates at idling speed.
15 % - 6 %
Tank level
7 minutes
100%
75%
50%
0%
A
B
0h
A engine torque
B time axis
ADVICE
This type of power reduction is "self-healing", i.e.:
For the full power of the engine to be restored, the tank level must be over 12%. The
tank level must be above 21% for the system to switch off the DEF control light and to
cancel the fault message.
DEF control light (Diesel Exhaust Fluid), AdBlue® YELLOW Warning
DEF control light (Diesel Exhaust Fluid), AdBlue® RED Warning
LIM control light, diesel engine torque limiter is active

Table of Contents