6.26 Electrics
ATTENTION
Hazard of damage to the electrical and electronic systems of the machine.
The main battery switch may not be switched off while the engine is running and
the ignition is switched on.
6.26.1 Voltage monitoring
The battery voltage is monitored by the system. If the voltage is too high or too low,
then the warning icon is displayed on the R-Touch. The battery voltage may not
exceed 32 V and may not fall below 24 V. As experience has shown, the machine can-
not be started with a battery voltage of less than 24 Volts.
When the generator fails, the following icon appears on the R-Touch.
6.26.2 Battery disconnect relay
76
When you disconnect the power supply (upward = OFF, downward = ON) at the main
battery switch (76) the power supply does not switch off until 6 minutes later (provided
the ignition lock is in position 0). If you forget to switch off the main battery switch (76)
the battery disconnect relay will switch off automatically 120 hours after switching off
the ignition. In this case you have to switch the main battery switch (76) OFF/ON once
before the next time you turn on the ignition.