Maintenance and Service
CVR gearbox (Traction drive)
402 / 564
7.5 CVR gearbox (Traction drive)
With the Constant Variable ROPA traction drive gearbox (1) the traction drive is driven
completely stepless from standstill to the programmed highest speed.
The oil level must be checked every 50 operating hours. Checking is performed using
the inspection glass (2).
It is situated in driving direction at the right side of the CVR gear.
Check the oil level before starting diesel engine! When the diesel engine has been
started, checking of the oil level is no longer possible. To read the oil level, the
machine must be standing on even and level ground and the engine must have been
shut off for at least 5 minutes. When the oil level rises or falls without evident reason,
indispensably call in a customer service mechanic.
The oil level can be read at the inspection glass. It must be within the inspection glass
range (in no case above the top edge of the inspection glass!).
The first oil change is required after 50 operating hours, further oil changes must be
performed annually.