Maintenance and Service
Lifter
438 / 564
7.9.7 Eccentric shaft bearing
Oil in the eccentric shaft bearings is a lifetime oil and must not be changed.
Check the oil level once a year. For this purpose, fully lower the lifting unit.
1
2
(1) Oil filling opening
(2) Oil level control screw
Prescribed oil variants: Gear oil
API GL5, SAE 90
Filling volume: each approx. 0.25 litres