TABLE 101 Association down alarm (continued)
Alarm Association down
Description This alarm is triggered when the stream control transmission protocol (SCTP)
association is down.
Recommended Actions Manual intervention is required.
Outbound routing failure
TABLE 102 Outbound routing failure alarm
Alarm Outbound routing failure
Alarm Type outboundRoutingFailure
Alarm Code 1636
Severity Critical
Aggregation Policy From the event code 1636 an alarm is raised for every 10 events. Alarm is raised
for 10 or more events or events occurring within a span of 60 seconds.
Attribute “mvnoId”=”2”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
“srcProcess”=”hip”, “operation”=”updateGprsLocationReq”,
“hlrInstance”=” Operator_HLR”, “ueImsi ”=” 04844624203918”
Displayed on the web
interface
Unable to route [{operation}] for IMSI [{ueImsi}] to HLR [{hlrInstance}]
Description This alarm is triggered when a transaction capabilities application part (TCAP)
message is unable to route to its destination.
Recommended Actions Manual intervention is required.
Did allocation failure
TABLE 103 Did allocation failure alarm
Alarm Did allocation failure
Alarm Type didAllocationFailure
Alarm Code 1637
Severity Critical
Aggregation Policy From the event code 1637 an alarm is raised for every 50 events. Alarm is raised
for 50 or more events or events occurring within a span of 60 seconds.
Attribute “mvnoId”=”2”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”hip”
Displayed on the web
interface
HIP unable to allocate new dialogue
Description This alarm is triggered when it is unable to allocate a dialogue identifier for a new
transaction. This indicates an overload condition.
Recommended Actions Manual intervention is required.
NOTE
Refer to Gr Interface Event on page 270.
Alarm Types
GR Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
106 Part Number: 800-71565-001 Rev A