TABLE 71 Data plane rebooted alarm (continued)
Alarm Data plane rebooted
Displayed on the web
interface
Data plane [{dpName||dpKey}] rebooted
Description This alarm is triggered when the data plane is rebooted.
Recommended Actions No action is required.
Data plane packet pool is under low water mark
TABLE 72 Data plane packet pool is under low water mark alarm
Alarm Data plane packet pool is under low water mark
Alarm Type dpPktPoolLow
Alarm Code 516
Severity Major
Aggregation Policy From the event code 516 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 518.
Attribute "dpKey"="xx:xx:xx:xx:xx:xx", "id"="x"
Displayed on the web
interface
Pool [{id}] on data plane [{dpName||dpKey}] is under low-water mark.
Description This alarm is triggered when the data core packet pool is below the water mark
level.
Recommended Actions The operator needs to check for network looping.
Data plane packet pool is under critical low water mark
TABLE 73 Data plane's packet pool is under critical low water mark alarm
Alarm Data plane packet pool is under critical low water mark
Alarm Type dpPktPoolCriticalLow
Alarm Code 517
Severity Critical
Aggregation Policy From the event code 517 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute dpKey="xx:xx:xx:xx:xx:xx", "id"="x"
Displayed on the web
interface
Pool [{id}] on data plane [{dpName||dpKey}] is under critical low-water mark.
Description This alarm is triggered when the data core packet pool reaches the critical water
mark level.
Recommended Actions The operator needs to check for network looping.
Data plane core dead
TABLE 74 Data plane core dead alarm
Alarm Data plane core dead
Alarm Type dpCoreDead
Alarm Types
Data Plane Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
92 Part Number: 800-71565-001 Rev A