EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
TABLE 183 Unknown realm event (continued)
Event Unknown realm
Event Code 1902
Severity Debug
Attribute “mvnoId”=”12”,“wlanId”=”1”,“zoneId”=”10”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
“srcProcess”=”aut”, “userName”=”acb@xyz.com", "SCGMgmtIp"="2.2.2.2",
“ueMacAddr”=”aa:bb:cc:gg:hh:ii”,“ueMsisdn”=”98787”,
“apIpAddress”=”10.1.4.11”
Displayed on the web
interface
[{srcProcess}] Failed to find realm for Accounting Packet received from AP
[{apIpAddress}] on {produce.short.name} [{SCGMgmtIp}], with username
[{userName}]
Description This event occurs when the controller fails to find realm configuration for the
accounting messages received from the AP.
AP accounting message decode failed
NOTE
This event is not applicable for vSZ-H.
TABLE 184 AP accounting message decode failed event
Event AP accounting message decode failed
Event Type apAcctMsgDecodeFailed
Event Code 1904
Severity Critical
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut”,
"SCGMgmtIp"="2.2.2.2", “apIpAddress”=”10.1.4.11”
Displayed on the web
interface
[{srcProcess}] Malformed Accounting Packet received from AP [{apIpAddress}] on
{produce.short.name} [{SCGMgmtIp}], with username [{userName}]
Description This event occurs when the AP accounting message decode fails due to receipt
of a malformed packet.
AP accounting retransmission message dropped
NOTE
This event is not applicable for vSZ-H.
TABLE 185 AP accounting retransmission message dropped event
Event AP accounting retransmission message dropped
Event Type apAcctRetransmittedMsgDropped
Event Code 1908
Severity Debug
Attribute mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="aut", "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii", “ueImsi"="12345",
"ueMsisdn"="98787" “apIpAddress”=”10.1.4.11”
Displayed on the web
interface
[{srcProcess}] Accounting message from AP [{apIpAddress}] on
{produce.short.name} [{SCGMgmtIp}] dropped, {produce.short.name} did not
receive Accounting start message.
Events Types
Accounting Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 147

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals