Following are the events related to control and data plane events.
DP connected on page 201
GtpManager (DP) disconnected on page 201
Session updated at DP on page 201
Session update at DP failed on page 202
Session deleted at DP on page 202
Session delete at DP failed on page 203
C2d configuration failed on page 203
DP connected
TABLE 333 DP connected event
Event DP connected
Event Type connectedToDblade
Event Code 1201
Severity Informational
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut”, “realm”=”NA”,
“ctrlBladeIp”=”1.1.1.1”, "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
The connectivity between Control plane [{ctrlBladeIp}] and Data plane
[{dataBladeIp}] is established at {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when control plane completes the configuration procedure
successfully.
GtpManager (DP) disconnected
TABLE 334 GtpManager (DP) disconnected event
Event GtpManager (DP) disconnected
Event Type lostCnxnToDblade
Event Code 1202
Severity Major
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut”, “realm”=”NA”,
“ctrlBladeIp”=”1.1.1.1”, "dataBladeIp"="3.3.3.3", "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
The connectivity between Control plane [{ctrlBladeIp}] and Data plane
[{dataBladeIp}] is lost at {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when either the transmission control protocol connection is lost
or when the control plane is unable to complete the configuration procedure.
Auto Clearance This event triggers the alarm 1202, which is auto cleared by the event code 1201.
Session updated at DP
TABLE 335 Session updated at DP event
Event Session updated at DP
Event Type sessUpdatedAtDblade
Event Code 1205
Events Types
Control and Data Plane Interface
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 201

Table of Contents

Related product manuals