TABLE 674 Diameter failover to alternate peer event (continued)
Event Diameter failover to alternate peer
Severity Major
Attribute “ctrlBladeMac”=“aa:bb:cc:dd:ee:ff”,”mvnoId”=“839f87c6-d116-497e-afce-
aa8157abd30c”, “srcProcess”=“<Application Name>“,”realm”=“ruckus.com”,
“originHost” =
“Node1”,”SCGMgmtIp”=“2.2.2.2”,”peerName”=“OCS1”,”peerRealmName” =
“Vodafone.com”,”altPeerName” = “OCS2”,”altPeerRealmName” =
“india.internal.net”“desc” = “Fwd to alt peer”
Displayed on the web
interface
[{srcProcess}] Fwd from Peer [{peerName}] to AltPeer [{altPeerName}] Realm
[{peerRealmName}] on {produce.short.name} [{SCGMgmtIp}]
Description This event occurs due to retransmission to an alternate peer.
Diameter fail back to peer
NOTE
This event is not applicable for vSZ-H.
TABLE 675 Diameter fail back to peer event
Event Diameter fail back to peer
Event Type diaFailbackToPeer
Event Code 1412
Severity Major
Attribute ”ctrlBladeMac”=“aa:bb:cc:dd:ee:ff”,”mvnoId”=“839f87c6-d116-497e-afce-
aa8157abd30c”, “srcProcess”=“<Application Name>“,”realm”=“ruckus.com”,
“originHost” = “Node1”,”SCGMgmtIp”=“2.2.2.2”,”peerName”=“OCS1”,
“peerRealmName” = “Vodafone.com”,”altPeerName” =
“OCS2”,”altPeerRealmName” = “india.internal.net”,”desc” = “Failback to main
peer”
Displayed on the web
interface
[{srcProcess}] Failback to Main Peer [{peerName}] Realm [{peerRealmName}] on
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs due to retransmission to the main peer in case of a fail back.
Diameter CEA unknown peer
NOTE
This event is not applicable for vSZ-H.
TABLE 676 Diameter CEA unknown peer event
Event Diameter CEA unknown peer
Event Type diaCEAUnknownPeer
Event Code 1414
Severity Critical
Attribute ”ctrlBladeMac”=“aa:bb:cc:dd:ee:ff”,”mvnoId”=“839f87c6-d116-497e-afce-
aa8157abd30c”, srcProcess”=“SessMgr”,
”realm”=“ruckus.com”,“originHost” = “Node1”,”
SCGMgmtIp”=“2.2.2.2”,”peerName”=“OCS8”,”peerRealmName” =
“Vodafone.com”,”desc” = “CEA received from Unknown peer
Events Types
System Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
322 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals