TABLE 35 Authentication fallback to primary alarm (continued)
Alarm Authentication fallback to primary
Recommended Actions No action is required.
AD/LDAP connectivity failure
TABLE 36 AD/LDAP connectivity failure alarm
Alarm AD/LDAP connectivity failure
Alarm Type racADLDAPFail
Alarm Code 1752
Severity Major
Aggregation Policy From the event code 1752 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “mvnoId”=12, “srcProcess”=”RAC”,
“authSrvrIp”=“1.1.1.1”, "SCGMgmtIp"="2.2.2.2"
“desc”= "Connection to AD/LDAP fails"
Displayed on the web
interface
[{srcProcess}] Connect to AD/LDAP[{authSrvrIp}] fails from SCG[{SCGMgmtIp}]
Description This alarm is triggered when RADIUS server fails to connect with AD/LDAP server.
Recommended Actions
• Check whether AD/LDAP server instance is running on the target
machine
• Check whether the AD/LDAP server can be reached from the controller
• Verify if AD/LDAP server instances are listening on ports 3268 and 389
• Verify if the requests are reaching AD/LDAP servers by any packet
capture tool (tcpdump, wireshark)
Bind fails with AD/LDAP
TABLE 37 Bind fails with AD/LDAP alarm
Alarm Bind fails with AD/LDAP
Alarm Type racADLDAPBindFail
Alarm Code 1753
Severity Major
Aggregation Policy From the event code 1753 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “mvnoId”=12, “srcProcess”=”RAC”,
“authSrvrIp”= “1.1.1.1”, “username”=“testuser’
"SCGMgmtIp"="2.2.2.2", “desc”=”Bind to AD/LDAP fails”
Displayed on the web
interface
[{srcProcess}] Bind to AD/LDAP[{authSrvrIp}] fails from SCG[{SCGMgmtIp}] for
User[{userName}]
Description This alarm is triggered when RADIUS server binding fails to AD/LDAP server.
Recommended Actions
• Verify the base and administrator domain names as configured in the
controller web interface
• Verify the administrator user name and password as configured in the
controller web interface