EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
TABLE 521 PDP update fail COA event (continued)
Event PDP update fail COA
Displayed on the web
interface
PDP context update initiated because of COA from AAA server [{gtpcIp}] failed for
UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at {produce.short.name}
[{SCGMgmtIp}]. Failure Cause [{cause}].
Description This event occurs when the packet data protocol update fails when initiating the
update process based on the change of authorization received from the external
AAA server.
PDNGW could not be resolved
TABLE 522 PDNGW could not be resolved event
Event PDNGW could not be resolved
Event Type pdnGwNotResolved
Event Code 1950
Severity Critical
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="sm_proces" "realm"="wlan.
3gppnetwork.org" "SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii"
"ueImsi"="12345",
"ueMsisdn"="98787" "apn"="ruckus.com"
Displayed on the web
interface
[{srcProcess}] APN [{apn}] could not be resolved on {produce.short.name}
[{SCGMgmtIp}], with username [{ueImsi}@{realm}]
Description This event occurs when the access point name is unable to resolve to PDN GW.
PDNGW version not supported
TABLE 523 PDNGW version not supported event
Event PDNGW version not supported
Event Type pdnGwVersionNotSupportedMsgReceived
Event Code 1952
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="sm_proces" "realm"="wlan.
3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii""ueImsi"="12345","ueMsisdn"="98787"
"APN"="ruckus.com", “pgwIp”=”1.1.1.1”
Displayed on the web
interface
[{srcProcess}] Version not supported message received from PDN GW with IP
[{pgwIp}] on {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the version is not supported for messages received from
PDN GW.
Associated PDNGW down
TABLE 524 Associated PDNGW down event
Event Associated PDNGW down
Event Type pdnGwAssociationDown
Event Code 1953
Events Types
Gn/S2a Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 267

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals