Data plane statistics update failed
TABLE 466 Data plane statistics update failed event
Event Data plane statistics update failed
Event Type dpUpdateStatisticFailed
Event Code 511
Severity Minor
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”, “wsgIP"=”xxx.xxx.xxx.xxx”
Displayed on the web
interface
Data plane [{dpName||dpKey}] failed to update its statistics to
{produce.short.name} [{cpName||wsgIP}].
Description This event occurs when the data plane fails to update statistics to the controller.
Data plane connected
TABLE 467 Data plane connected event
Event Data plane connected
Event Type dpConnected
Event Code 512
Severity Informational
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”, “wsgIP"=”xxx.xxx.xxx.xxx”
Displayed on the web
interface
Data plane [{dpName||dpKey}] connected to {produce.short.name} [{cpName||
wsgIP}].
Description This event occurs when the data plane connects to the controller.
Data plane disconnected
TABLE 468 Data plane disconnected event
Event Data plane disconnected
Event Type dpDisconnected
Event Code 513
Severity Critical
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”, “wsgIP"=”xxx.xxx.xxx.xxx”
Displayed on the web
interface
Data plane [{dpName||dpKey}] disconnected from {produce.short.name}
{cpName||wsgIP}].
Description This event occurs when the data plane disconnects from the controller.
Auto Clearance This event triggers the alarm 503, which is auto cleared by the event code 512.
Data plane physical interface down
TABLE 469 Data plane physical interface down event
Event Data plane physical interface down
Event Type dpPhyInterfaceDown
Event Code 514
Events Types
Data Plane Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 247