EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #137 background imageLoading...
Page #137 background image
Disk usage threshold exceeded
TABLE 164 Disk usage threshold exceeded alarm
Alarm Disk usage threshold exceeded
Alarm Type diskUsageThresholdExceeded
Alarm Code 952
Severity Critical
Aggregation Policy From the event code 952 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 955.
Attribute “nodeName”=”xxx”, “nodeMac”=”xx:xx:xx:xx:xx:xx”, “perc”=”XX”
Displayed on the web
interface
Disk usage threshold [{perc}%] exceeded on control plane [{nodeName}-C].
Description This alarm is triggered when the disk usage exceeds the threshold limit. The disk
threshold value is 80%.
Recommended Actions Check the backup files for disk usage. Each backup file may occupy a large disk
space based on the database size. If there are multiple backup files/versions in
the controller, it is recommended to delete the older backup files to free disk
usage. If the problem persists, please take a screen shot and send it to Ruckus
Wireless support.
License threshold exceeded
TABLE 165 License threshold exceeded alarm
Alarm License threshold exceeded
Alarm Type licenseThresholdExceeded
Alarm Code 960
Severity Critical 90%
Major 80%
Aggregation Policy From the event code 960 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “perc”=”xxx”, "nodeMac"="xx:xx:xx:xx:xx:xx”, "nodeName"="box1",
"licenseType"="SG00"
Displayed on the web
interface
[{licenseType}] limit reached at [{perc}%].
Description This alarm is triggered when maximum number of licenses is utilized.
Recommended Actions Check the license purchase and usage numbers. Alternatively, you would need to
buy new licenses.
Rate limit for TOR surpassed
TABLE 166 Rate limit for TOR surpassed alarm
Alarm Rate limit for TOR surpassed
Alarm Type rateLimitTORSurpassed
Alarm Code 1302
Severity Critical
Alarm Types
Threshold Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 137

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals