EasyManua.ls Logo

Ruckus Wireless Virtual SmartZone High Scale - AP Tunnel Disconnected; AP Softgre Tunnel Fails over Primary to Secondary; AP Softgre Tunnel Fails over Secondary to Primary

Ruckus Wireless Virtual SmartZone High Scale
341 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TABLE 703 AP created a tunnel event (continued)
Event AP created a tunnel
Severity Informational
Attribute "apMac"="xx:xx:xx:xx:xx:xx", "dpIP"="xxx.xxx.xxx.xxx",
Displayed on the web
interface
AP [{apName&&apMac}] created a tunnel to data plane [{dpIP}].
Description This event occurs when AP creates a tunnel to the data plane.
AP tunnel disconnected
TABLE 704 AP tunnel disconnected event
Event AP tunnel disconnected
Event Type apTunnelDisconnected
Event Code 610
Severity Informational
Attribute “apMac”=”xx:xx:xx:xx:xx:xx”, “dpIP”=”xxx.xxx.xxx.xxx”, “reason”=”xxxxx”
Displayed on the web
interface
AP [{apName&&apMac}] disconnected from data plane [{dpIP}]. Reason:
[{reason}]
Description This event occurs when AP disconnects from the data plane.
NOTE
Event codes 601 to 610 are not applicable for vSZ-H.
AP softGRE tunnel fails over primary to secondary
TABLE 705 AP softGRE tunnel fails over primary to secondary event
Event AP softGRE tunnel fails over primary to secondary
Event Type apSoftGRETunnelFailoverPtoS
Event Code 611
Severity Warning
Attribute “apMac"="xx:xx:xx:xx:xx:xx", "primaryGRE"="xxx.xxx.xxx.xxx",
"secondaryGRE"="xxx.xxx.xxx.xxx "
Displayed on the web
interface
AP [{apName&&apMac}] fails over from primaryGRE [{primaryGRE}] to
secondaryGRE[{secondaryGRE}].
Description This event occurs when AP moves from a primary to a secondary GRE.
AP softGRE tunnel fails over secondary to primary
TABLE 706 AP softGRE tunnel fails over secondary to primary event
Event AP softGRE tunnel fails over secondary to primary
Event Type apSoftGRETunnelFailoverStoP
Event Code 612
Severity Warning
Attribute "apMac"="xx:xx:xx:xx:xx:xx", "primaryGRE"="xxx.xxx.xxx.xxx",
"secondaryGRE"="xxxx"
Events Types
Tunnel Events - Access Point (AP)
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 333

Table of Contents