TABLE 703 AP created a tunnel event (continued)
Event AP created a tunnel
Severity Informational
Attribute "apMac"="xx:xx:xx:xx:xx:xx", "dpIP"="xxx.xxx.xxx.xxx",
Displayed on the web
interface
AP [{apName&&apMac}] created a tunnel to data plane [{dpIP}].
Description This event occurs when AP creates a tunnel to the data plane.
AP tunnel disconnected
TABLE 704 AP tunnel disconnected event
Event AP tunnel disconnected
Event Type apTunnelDisconnected
Event Code 610
Severity Informational
Attribute “apMac”=”xx:xx:xx:xx:xx:xx”, “dpIP”=”xxx.xxx.xxx.xxx”, “reason”=”xxxxx”
Displayed on the web
interface
AP [{apName&&apMac}] disconnected from data plane [{dpIP}]. Reason:
[{reason}]
Description This event occurs when AP disconnects from the data plane.
NOTE
Event codes 601 to 610 are not applicable for vSZ-H.
AP softGRE tunnel fails over primary to secondary
TABLE 705 AP softGRE tunnel fails over primary to secondary event
Event AP softGRE tunnel fails over primary to secondary
Event Type apSoftGRETunnelFailoverPtoS
Event Code 611
Severity Warning
Attribute “apMac"="xx:xx:xx:xx:xx:xx", "primaryGRE"="xxx.xxx.xxx.xxx",
"secondaryGRE"="xxx.xxx.xxx.xxx "
Displayed on the web
interface
AP [{apName&&apMac}] fails over from primaryGRE [{primaryGRE}] to
secondaryGRE[{secondaryGRE}].
Description This event occurs when AP moves from a primary to a secondary GRE.
AP softGRE tunnel fails over secondary to primary
TABLE 706 AP softGRE tunnel fails over secondary to primary event
Event AP softGRE tunnel fails over secondary to primary
Event Type apSoftGRETunnelFailoverStoP
Event Code 612
Severity Warning
Attribute "apMac"="xx:xx:xx:xx:xx:xx", "primaryGRE"="xxx.xxx.xxx.xxx",
"secondaryGRE"="xxxx"
Events Types