TABLE 86 GGSN not resolved alarm (continued)
Alarm GGSN not resolved
Aggregation Policy From the event code 1215 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “mvnoId”=”12”,“wlanId”=”1”, “zoneId”=”10”,
“ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut”,
“realm”=”wlan.3gppnetwork.org", “gtpcIp”=”5.5.5.5”,
"apn"="ruckuswireless.com", "SCGMgmtIp"="2.2.2.2",
“ueMacAddr”=”aa:bb:cc:gg:hh:ii”, “ueImsi”=”12345”,
“ueMsisdn”=”98787”,
Displayed on the web
interface
Failed to resolve GGSN from APN [{apn}] for UE with IMSI [{ueImsi}] and MSISDN
[{ueMsisdn}]
Description This alarm is triggered when the access point name (APN) fails at GGSN.
Recommended Actions Manual intervention is required. Correct the DNS configuration in the controller
web interface.
PDNGW could not be resolved
TABLE 87 PDNGW could not be resolved alarm
Alarm PDNGW could not be resolved
Alarm Type pdnGwNotResolved
Alarm Code 1950
Severity Critical
Aggregation Policy From the event code 1950 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute mvnoId”=12 “wlanId”=1 “zoneId”=”10”, “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
srcProcess”=”aut” “realm”= ”wlan.mnc080.mcc405.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" “ueMacAddr”=”aa:bb:cc:gg:hh:ii” “ueImsi”=”12345”
“ueMsisdn”=”98787” “APN”=”ruckus.com”
Displayed on the web
interface
[{srcProcess}] APN [{apn}] could not be resolved on {produce.short.name}
[{SCGMgmtIp}], with username [{ueImsi}@{realm}]
Description This alarm is triggered when the APN is unable to resolve to PDN Gateway (PDN
GW).
Recommended Actions Modify the DNS server configuration in the controller web interface.
PDNGW version not supported
TABLE 88 PDNGW version not supported alarm
Alarm PDNGW version not supported
Alarm Type pdnGwVersionNotSupportedMsgReceived
Alarm Code 1952
Severity Major
Aggregation Policy From the event code 1952 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”sm_process” “realm”= ”NA"
“gtpcIp”=”5.5.5.5” “pgwIp”=”1.1.1.1” "SCGMgmtIp"="2.2.2.2"
Alarm Types
Gn/S2a Interface Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals