TABLE 556 ipmiThempP event (continued)
Event ipmiThempP
Displayed on the web
interface
Processor [{id}] temperature [{status}] on control plane [{nodeMac}]
Description This event is triggered when the threshold value is in the range of 1
0
to 11
0
Celsius. The default threshold is 11
0
C.
Auto Clearance This event triggers the alarm 907, which is auto cleared by the event code 932.
ipmiThempHSBP
TABLE 557 ipmiThempHSBP event
Event ipmiThempHSBP
Event Type ipmiThempHSBP
Event Code 908
Severity Majorf
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Hot swap backplane temperature [{status}] on control plane [{nodeMac}]
Description This event occurs when the hot swap back plane temperature status in the range
of 9
0
Celsius to 55
0
Celsius. The default threshold is 55
0
C.
Auto Clearance This event triggers the alarm 908, which is auto cleared by the event code 933.
ipmiFan
TABLE 558 ipmiFan event
Event ipmiFan
Event Type ipmiFan
Event Code 909
Severity Major
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
System fan [{id}] module [{status}] on control plane [{nodeMac}]
Description This event occurs when the system fan module status is sent.
Auto Clearance This event triggers the alarm 909, which is auto cleared by the event code 934.
ipmiPower
TABLE 559 ipmiPower event
Event ipmiPower
Event Type ipmiPower
Event Code 910
Severity Major
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Events Types
IPMI Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
280 Part Number: 800-71565-001 Rev A