• Association establishment failed on page 273
• Association down on page 273
• Association up on page 273
• Send auth info success on page 274
• Auth info sending failed on page 274
• GPRS location update succeeded on page 274
• GPRS location update failed on page 274
• Insert sub data success on page 275
• Insert sub data failed on page 275
• Outbound routing failure on page 275
• Did allocation failure on page 276
• Restore data success on page 276
• Restore data failed on page 276
Destination not reachable
TABLE 532 Destination not reachable event
Event Destination not reachable
Event Type destNotRecheable
Event Code 1618
Severity Critical
Attribute "mvnoId"="2" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="hip"
"pointCode"="1.1.1"
Displayed on the web
interface
Remote Point Code [{pointCode}] is unavailable
Description This event occurs when the point code is unreachable due to a pause indicator
Auto Clearance This event triggers the alarm 1618, which is auto cleared by the event code 1620.
Destination available
TABLE 533 Destination available event
Event Destination available
Event Type destAvailable
Event Code 1620
Severity Critical
Attribute "mvnoId"="2" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="hip"
"pointCode"="1.1.1"
Displayed on the web
interface
Remote Point Code [{pointCode}] is available
Description This event occurs when the point code is available due to the resume indicator.
Events Types
Gr Interface Event
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 271