AP rebooted by system
TABLE 27 AP rebooted by system alarm
Alarm AP rebooted by system
Alarm Type apRebootBySystem
Alarm Code 302
Severity Major
Aggregation Policy From the event code 302 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “apMac”=”xx:xx:xx:xx:xx:xx”, “reason”=”xxxxx”
Displayed on the web
interface
AP [{apName&&apMac}] rebooted by the system because of [{reason}]
Description This alarm is triggered when system reboots the AP.
Recommended Actions Check the reasons for the reboot. If the reason is unknown, retrieve the AP
support text and send it to Ruckus support.
AP disconnected
TABLE 28 AP disconnected alarm
Alarm AP disconnected
Alarm Type apConnectionLost
Alarm Code 303
Severity Major
Aggregation Policy From the event code 303 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm is auto cleared with the event code 312
Attribute “apMac”=”xx:xx:xx:xx:xx:xx”
Displayed on the web
interface
AP [{apName&&apMac}] disconnected
Description This alarm is triggered when the AP disconnects from the controller.
Recommended Actions Check the network and the communicator process on the controller. Try
rebooting the AP locally.
AP deleted
TABLE 29 AP deleted alarm
Alarm AP deleted
Alarm Type apDeleted
Alarm Code 306
Severity Major
Aggregation Policy From the event code 313 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “apMac”=”xx:xx:xx:xx:xx:xx”
Displayed on the web
interface
AP [{apName&&apMac}] deleted
Alarm Types
AP State Change Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
70 Part Number: 800-71565-001 Rev A