TABLE 45 Node out of service alarm (continued)
Alarm Node out of service
Recommended Actions The operator/user needs to check the application/interface state.
Cluster in maintenance state
TABLE 46 Cluster in maintenance state alarm
Alarm Cluster in maintenance state
Alarm Type clusterInMaintenanceState
Alarm Code 804
Severity Critical
Aggregation Policy From the event code 807 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 808.
Attribute “clusterName”=”xxx”
Displayed on the web
interface
Cluster [{clusterName}] is in maintenance state
Description This alarm is triggered when a cluster is in a maintenance state.
Recommended Actions Possible causes:
• The entire system backup is in process.
• In a two-node cluster, the remove-node process is working.
For any other cause, please send the complete system log files (stored in the path
- /opt/ ruckuswireless/controller/log/system to Ruckus support
for analysis.
Cluster backup failed
TABLE 47 Cluster backup failed alarm
Alarm Cluster backup failed
Alarm Type backupClusterFailed
Alarm Code 805
Severity Major
Aggregation Policy From the event code 810 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 809.
Attribute “clusterName”=”xxx”
Displayed on the web
interface
Cluster [{clusterName}] backup failed. Reason:[{reason}].
Description This alarm is triggered when a cluster backup fails.
Recommended Actions Check the disk usage. Try restoring the communication between nodes for a few
more times. If the backup continues to fail or if you encounter Python script
errors, please collect the complete system log files (stored in the path -
/opt/ ruckuswireless/controller/log/system to Ruckus support for
analysis. Possible causes:
• Insufficient disk space.
• Communication between nodes may be broken.
Alarm Types
Cluster Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
80 Part Number: 800-71565-001 Rev A