EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #130 background imageLoading...
Page #130 background image
Diameter CER error
NOTE
This alarm is not applicable for vSZ-H.
TABLE 150 Diameter CER error alarm
Alarm Diameter CER error
Alarm Type diaCERError
Alarm Code 1404
Severity Critical
Aggregation Policy A single event triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “mvnoId”=12 “srcProcess”=”<Application
Name>” “realm”=”ruckus.com" “originHost” = “Node1” "SCGMgmtIp"="2.2.2.2"
“peerIp” = “3.3.3.3” “peerName” = “OCS1” “peerRealmName” =
“organization.com” “desc” = ”Failed to read from peer socket”
Displayed on the web
interface
[{srcProcess}] Failed to decode CER from Peer [{peerName}] Realm
[{peerRealmName}] on {produce.short.name} [{SCGMgmtIp}]
Description This alarm is triggered when the diameter stack fails to decode the capabilities
exchange request (CER) received from peer.
Recommended Actions Check if the transport is up for the peer. Peer application may not be running.
Diameter peer add error
NOTE
This alarm is not applicable for vSZ-H.
TABLE 151 Diameter peer add error alarm
Alarm Diameter peer add error
Alarm Type diaPeerAddError
Alarm Code 1407
Severity Critical
Aggregation Policy A single event triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “mvnoId”=12 “srcProcess”=”<Application
Name>” “realm”=”ruckus.com" “originHost” = “Node1” "SCGMgmtIp"="2.2.2.2"
“peerIp” = “3.3.3.3” “peerName” = “OCS1” “peerRealmName” =
“organization.com” “desc” = ”Failed to add Peer” “cause”=”Cause Value”
Displayed on the web
interface
[{srcProcess}] Failed to add Peer [{peerName}], Realm [{peerRealmName}] on
{produce.short.name} [{SCGMgmtIp}]
Description This alarm is triggered when the diameter stack fails to add a peer to the peer
table.
Recommended Actions Check if the peer IP address is reachable and if the peer responds to the
configured port.
Alarm Types
System Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
130 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals