Cluster upload AP firmware failed
TABLE 57 Cluster upload AP firmware failed alarm
Alarm Cluster upload AP firmware failed
Alarm Type clusterUploadAPFirmwareFailed
Alarm Code 850
Severity Major
Aggregation Policy From the event code 850 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 849
Attribute "clusterName"="xx"
Displayed on the web
interface
Cluster [{clusterName}] upload AP firmware failed.
Description This alarm is triggered when the cluster upload to AP firmware fails.
Recommended Actions It is recommended that the operator uploads the AP patch.
Cluster add AP firmware failed
TABLE 58 Cluster add AP firmware failed alarm
Alarm Cluster add AP firmware failed
Alarm Type clusterAddAPFirmwareFailed
Alarm Code 853
Severity Major
Aggregation Policy From the event code 853 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 852
Attribute "clusterName"="xx"
Displayed on the web
interface
Cluster [{clusterName}] add AP firmware failed.
Description This alarm is triggered when the cluster upload to AP firmware fails.
Recommended Actions It is recommended that the operator applies the AP patch.
Unsync NTP time
TABLE 59 Unsync NTP time alarm
Alarm Unsync NTP time
Alarm Type unsyncNTPTime
Alarm Code 855
Severity Major
Aggregation Policy From the event code 855 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute "nodeName"="xx", "reason"="xx", "status"="xx"
Displayed on the web
interface
Node [{nodeName}] time is not synchronized because of [{reason}]. The time
difference is [{status}] seconds.
Description This alarm is triggered when the cluster time is not synchronized.
Alarm Types
Cluster Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 85

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals