Association establishment failed
TABLE 537 Association establishment failed event
Event Association establishment failed
Event Type assocEstbFailed
Event Code 1626
Severity Critical
Attribute "mvnoId"="3" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="hip"
"srcIP"="10.1.4.10" "srcPort"="2960" "destIP"="10.1.4.20" "destPort"="2960"
Displayed on the web
interface
Failed to establish SCTP association. SCTP Abort received from srcIP [{srcIP}],
srcPort [{srcPort}], destIP[{destIP}], destPort [{destPort}]
Description This event occurs when it is unable to establish an association to the controller/
IPSP.
Auto Clearance This event triggers the alarm 1626, which is auto cleared by the event code 1628.
Association down
TABLE 538 Association down event
Event Association down
Event Type assocDown
Event Code 1627
Severity Critical
Attribute "mvnoId"="3" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="hip"
"srcIP"="10.1.4.10" "srcPort"="2960" "destIP"="10.1.4.20" "destPort"="2960"
Displayed on the web
interface
SCTP association DOWN srcIP [{srcIP}], srcPort [{srcPort}], destIP[{destIP}],
destPort [{destPort}]
Description This event occurs when the stream control transmission protocol (SCTP)
association is down.
Auto Clearance This event triggers the alarm 1627, which is auto cleared by the event code 1628.
Association up
TABLE 539 Association up event
Event Association up
Event Type assocUp
Event Code 1628
Severity Critical
Attribute "mvnoId"="3" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="hip"
"srcIP"="10.1.4.10" "srcPort"="2960" "destIP"="10.1.4.20" "destPort"="2960"
Displayed on the web
interface
SCTP association UP. srcIP [{srcIP}], srcPort [{srcPort}], destIP[{destIP}], destPort
[{destPort}]
Description This event occurs when the SCTP association is UP.
Events Types
Gr Interface Event
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 273

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals