EasyManua.ls Logo

Ruckus Wireless Virtual SmartZone High Scale - Cluster Alarms; New node failed to join

Ruckus Wireless Virtual SmartZone High Scale
341 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cluster Alarms
Following are the alarms related to cluster.
New node failed to join on page 78
Node removal failed on page 79
Node out of service on page 79
Cluster in maintenance state on page 80
Cluster backup failed on page 80
Cluster restore failed on page 81
Cluster upgrade failed on page 81
Cluster application stopped on page 82
Node bond interface down on page 82
Node physical interface down on page 83
Cluster node rebooted on page 83
Cluster node shut down on page 83
Disk usage exceed threshold on page 84
Cluster out of service on page 84
Cluster upload AP firmware failed on page 85
Cluster add AP firmware failed on page 85
Unsync NTP time on page 85
Cluster upload KSP file failed on page 86
Configuration backup failed on page 86
Configuration restore failed on page 86
New node failed to join
TABLE 43 New node failed to join alarm
Alarm New node failed to join
Alarm Type newNodeJoinFailed
Alarm Code 801
Severity Critical
Aggregation Policy From the event code 803 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 802.
Attribute “clusterName”=”xxx”, “nodeName”=”xxx”,
“nodeMac”=” xx:xx:xx:xx:xx:xx”
Displayed on the web
interface
New node [{nodeMac}] ([{nodeName}]) failed to join cluster [{clusterName}]
Description This alarm is triggered when a node fails to join a cluster session. The web
interface displays the error message.
Recommended Actions When the operation fails, the user can run the join process. If it continues to fail,
please send the complete system log files (stored in the path -
Alarm Types
Cluster Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
78 Part Number: 800-71565-001 Rev A

Table of Contents

Related product manuals