EasyManua.ls Logo

Ruckus Wireless Virtual SmartZone High Scale - TTG Session Warning Threshold; TTG Session Major Threshold; TTG Session Critical Threshold

Ruckus Wireless Virtual SmartZone High Scale
341 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TTG session warning threshold
NOTE
This event is not applicable for vSZ-H.
TABLE 578 TTG session warning threshold event
Event TTG session warning threshold
Event Type ttgSessionWarningThreshold
Event Code 1240
Severity Warning
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut/lic”
Displayed on the web
interface
The licensed sessions of {produce.short.name} [{SCGMgmtIp}] have reached
warning level.
Description This event occurs when the number of user equipment attached to the system
has reached the critical threshold limit.
TTG session major threshold
NOTE
This event is not applicable for vSZ-H.
TABLE 579 TTG session major threshold event
Event TTG session major threshold
Event Type ttgSessionMajorThreshold
Event Code 1241
Severity Major
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut/lic”
Displayed on the web
interface
The licensed sessions of {produce.short.name} [{SCGMgmtIp}] have reached
major level.
Description This event occurs when the number of user equipment attached to the system
has reached the major threshold limit.
TTG session critical threshold
NOTE
This event is not applicable for vSZ-H.
TABLE 580 TTG session critical threshold event
Event TTG session critical threshold
Event Type ttgSessionCriticalThreshold
Event Code 1242
Severity Critical
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”aut/lic”
Displayed on the web
interface
The licensed sessions of {produce.short.name} [{SCGMgmtIp}] have reached
critical level.
Description This event occurs when the number of user equipment attached to the system
has reached the critical threshold limit.
Events Types
Licensing Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 287