RADIUS server unreachable
TABLE 10 RADIUS server unreachable alarm
Alarm RADIUS server unreachable
Alarm Type radiusServerUnreachable
Alarm Code 2102
Severity Major
Aggregation Policy From the event code 2102 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “apMac="xx:xx:xx:xx:xx:xx","ip"="17.0.0.12","fwVersion"="3.2.0.0.x","model"="Z
F7982","zoneUUID"="f77a8816-3049-40cd-8484-82919275ddc3","zoneName"=
"Default Zone","apLocation"="".
Auto Clearance The alarm is auto cleared with the event code 2101.
Displayed on the web
interface
AP [{apName&&apMac}] is unable to reach radius server [{ip}].
Description This alarm is triggered when AP is unable to reach RADIUS server.
Recommended Actions Check the network connectivity between AP and RADIUS server.
LDAP server unreachable
TABLE 11 LDAP server unreachable alarm
Alarm LDAP server unreachable
Alarm Type ldapServerUnreachable
Alarm Code 2122
Severity Major
Aggregation Policy From the event code 2122 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “apMac="xx:xx:xx:xx:xx:xx","ip"="17.0.0.12","fwVersion"="3.2.0.0.x","model"="Z
F7982","zoneUUID"="f77a8816-3049-40cd-8484-82919275ddc3","zoneName"=
"Default Zone","apLocation"=""
Auto Clearance The alarm is auto cleared with the event code 2121.
Displayed on the web
interface
AP [{apName&&apMac}] is unable to reach LDAP server [{ip}].
Description This alarm is triggered when AP is unable to reach LDAP server.
Recommended Actions Check the network connectivity between AP and LDAP server.
AD server unreachable
TABLE 12 AD server unreachable alarm
Alarm AD server unreachable
Alarm Type adServerUnreachable
Alarm Code 2142
Severity Major
Aggregation Policy From the event code 2142 an alarm is raised for every event. A single event
triggers a single alarm.
Alarm Types
AP Authentication Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
62 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals