Data plane disconnected
TABLE 69 Data plane disconnected alarm
Alarm Data plane disconnected
Alarm Type dpDisconnected
Alarm Code 503
Severity Critical
Aggregation Policy From the event code 513 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 512.
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”, “wsgIP"=”xxx.xxx.xxx.xxx”
Displayed on the web
interface
Data plane [{dpName||dpKey}] disconnected from {produce.short.name}
[{cpName||wsgIP}]
Description This alarm is triggered when the data plane gets disconnected from the controller
since it fails to update its status to the control plane.
Recommended Actions Check if the communicator is still alive and if the cluster interface is working.
Data plane physical interface down
TABLE 70 Data plane physical interface down alarm
Alarm Data plane physical interface down
Alarm Type dpPhyInterfaceDown
Alarm Code 504
Severity Critical
Aggregation Policy From the event code 514 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 515.
Attribute “portID”=”xx”, “dpKey”=”xx:xx:xx:xx:xx:xx”
Displayed on the web
interface
Network link of port [{portID}] on data plane [{dpName||dpKey}] is down
Description This alarm is triggered when the physical interface link of the data plane is down
due to the fiber cable connection.
Recommended Actions Check if the fiber cable between the data plane and the switch is firmly
connected.
Data plane rebooted
TABLE 71 Data plane rebooted alarm
Alarm Data plane rebooted
Alarm Type dpReboot
Alarm Code 510
Severity Minor
Aggregation Policy From the event code 506 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”,
Alarm Types
Data Plane Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide