ipmiCurrent
TABLE 114 ipmiCurrent alarm
Alarm ipmiCurrent
Alarm Type ipmiCurrent
Alarm Code 911
Severity Major
Aggregation Policy From the event code 911 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 936.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Power supply [{id}] +12V% of maximum current output [{status}] on control plane
[{nodeMac}]
Description This alarm is triggered when the control plane’s power supply shows the status as
maximum voltage.
Recommended Actions Replace the power supply cord. If the problem persists, replace the mother
board.
ipmiFanStatus
TABLE 115 ipmiFanStatus alarm
Alarm ipmiFanStatus
Alarm Type ipmiFanStatus
Alarm Code 912
Severity Major
Aggregation Policy From the event code 912 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 937.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Fan module [{id}] [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s fan module shows the status as
not working.
Recommended Actions Replace the fan module.
ipmiPsStatus
TABLE 116 ipmiPsStatus alarm
Alarm ipmiPsStatus
Alarm Type ipmiPsStatus
Alarm Code 913
Severity Major
Aggregation Policy From the event code 913 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 938.
Alarm Types
IPMI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 113