TABLE 106 ipmiThempFP alarm (continued)
Alarm ipmiThempFP
Description This alarm is triggered due to increase/decrease of the front panel temperature
status of the control plane. Front panel threshold temperatures are in the range of
5
0
Celsius to 44
0
Celsius. The default threshold is 44
0
C.
Recommended Actions Check the fan module. Decrease the ambient temperature if the fan module is
working.
ipmiThempIOH
TABLE 107 ipmiThempIOH alarm
Alarm ipmiThempIOH
Alarm Type ipmiThempIOH
Alarm Code 904
Severity Major
Aggregation Policy From the event code 904 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 929.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Chipset temperature [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the chip set temperature status on the control plane
increases/decreases. IOH thermal margin threshold temperatures are in the range
of -20
0
Celsius to 5
0
Celsius. The default threshold is 5
0
C.
Recommended Actions Check the fan module. Decrease the ambient temperature if the fan module is
working.
ipmiThempMemP
TABLE 108 ipmiThempMemP alarm
Alarm ipmiThempMemP
Alarm Type ipmiThempMemP
Alarm Code 905
Severity Major
Aggregation Policy From the event code 905 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 930.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Processor [{id}] memory temperature [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s processor memory shows the
status as either an increase/decrease in temperature. Process 1 memory thermal
margin threshold temperatures are in the range of -20
0
Celsius to 5
0
Celsius. The
default threshold is 5
0
C.
Recommended Actions Check the fan module. Decrease the ambient temperature if the fan module is
working.
Alarm Types
IPMI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
110 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals