PDP context established
TABLE 505 PDP context established event
Event PDP context established
Event Type pdpCtxtEstablished
Event Code 1216
Severity Debug
Attribute "mvnoId"=12,"wlanId"=1 "zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
Displayed on the web
interface
PDP context created for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when packet data protocol is established.
PDP create failed
TABLE 506 PDP create failed event
Event PDP create failed
Event Type crtPdpFailed
Event Code 1217
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"cause"="cause of error"
Displayed on the web
interface
PDP context create failed for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at
{produce.short.name} [{SCGMgmtIp}]. Cause [{cause}]
Description This event occurs when create packet data protocol fails.
PDP update by HLR succeeded
TABLE 507 PDP update by HLR succeeded event
Event PDP update by HLR succeeded
Event Type initPdpUpdSuccHlr
Event Code 1218
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"hlrEvent"="<event received from HLR>"
Displayed on the web
interface
PDP context updated for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at
{produce.short.name} [{SCGMgmtIp}] because of [hlrEvent] from HLR
Description This event occurs when packet data protocol context is updated successfully.
Update is initiated by tunneling termination gateway (TTG) control plane as a
result of the home location register (HLR) initiation.
Events Types
Gn/S2a Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 261