Node physical interface down
TABLE 52 Node physical interface down alarm
Alarm Node physical interface down
Alarm Type nodePhyInterfaceDown
Alarm Code 810
Severity Critical
Aggregation Policy From the event code 824 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 825.
Attribute “nodeName”=”xxx”, “nodeMac”=” xx:xx:xx:xx:xx:xx”,
“ifName”=”xxxx”
Displayed on the web
interface
Physical network interface [{networkInterface||ifName}] on node [{nodeName}] is
down.
Description This alarm is triggered when the physical interface of a node is down.
Recommended Actions Check if the network cables of both the physical interfaces are broken.
Alternatively, check if the physical interfaces for this bond interface are broken.
Please send the log files stored in the path -
/opt/ ruckuswireless/controller/log/system to Ruckus support for
analysis.
Cluster node rebooted
TABLE 53 Cluster node rebooted alarm
Alarm Cluster node rebooted
Alarm Type nodeRebooted
Alarm Code 811
Severity Major
Aggregation Policy From the event code 826 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute "nodeName”=”xxx”, “nodeMac”=”xxx”
Displayed on the web
interface
Node [{nodeName}] in cluster [{clusterName}] rebooted
Description This alarm is triggered when the node is rebooted.
Recommended Actions Usually, this occurs due to user actions like manual reboot of a node, upgrade or
restoration of a cluster. Please send the log files stored in the path - /opt/
ruckuswireless/controller/log/system to Ruckus support for
analysis.
Cluster node shut down
TABLE 54 Cluster node shut down alarm
Alarm Cluster node shut down
Alarm Type nodeShutdown
Alarm Code 813
Severity Major
Alarm Types
Cluster Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 83

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals