EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #193 background imageLoading...
Page #193 background image
TABLE 311 Fast re-authentication succeeded event (continued)
Event Fast re-authentication succeeded
Displayed on the web
interface
Fast re-auth ID based authentication successful for UE with IMSI [{ueImsi}] and
MSISDN [{ueMsisdn}]. {produce.short.name} used is [{SCGMgmtIp}]
Description This event occurs after resending RADIUS accept back to AP. This event is
applicable when, the {produce.short.name} acts as a hosted AAA server and for
TTG/PDG session.
Note: FastReauth ID is used for authentication.
Fast re-authentication failed
NOTE
This event is not applicable for vSZ-H.
TABLE 312 Fast re-authentication failed event
Event Fast re-authentication failed
Event Type fastReauthFailed
Event Code 1609
Severity Debug
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"=" radiusd" "realm"="wlan.3gppnetwork.org"
"SCGMgmtIp"="2.2.2.2" "ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345"
"ueMsisdn"="98787" "cause"="<Cause of failure>" "authType"="EAP-SIM/AKA"
Displayed on the web
interface
Fast re-auth ID based authentication failed for UE with IMSI [{ueImsi}] and
MSISDN [{ueMsisdn}]. Cause = [{cause}]. {produce.short.name} used is
[{SCGMgmtIp}]
Description This event occurs when the RADIUS reject is sent back for fast reauthentication.
This event applies when the controller acts as a host AAA server. The MS-ISDN is
provided (if available).
Note: Attribute FastReuathID is used for reauthentication.
Authentication failed over to secondary
TABLE 313 Authentication failed over to secondary event
Event Authentication failed over to secondary
Event Type authFailedOverToSecondary
Event Code 1651
Severity Major
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“primary"=”20.20.20.20” “secondary”=”30.30.30.30” "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the secondary authentication RADIUS server is available
after the primary server becomes zombie or dead.
Events Types
Authentication Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 193

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals