Configuration update failed
TABLE 449 Configuration update failed event
Event Configuration update failed
Event Type cfgUpdFailed
Event Code 1008
Severity Debug
Attribute “ctrlBladeMac"="aa:bb:cc:dd:ee:ff" , "srcProcess"="cnr" "realm"="NA"
"processName"="aut" "SCGMgmtIp"="x.x.x.x" "cause"="xx"
Displayed on the web
interface
Failed to apply configuration [{cause}] in [{processName}] process at
{produce.short.name} [{SCGMgmtIp}].
Description This event occurs when the CNR receives a negative acknowledgment when
applying the configuration settings to the module. Possible cause is that a
particular process/module is down.
Configuration receive failed
TABLE 450 Configuration receive failed event
Event Configuration receive failed
Event Type cfgRcvFailed
Event Code 1009
Severity Debug
Attribute "ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, “srcProcess”=”cnr” “realm”=”NA”
"SCGMgmtIp"="x.x.x.x", “cause”=”xx”
Displayed on the web
interface
Failed to fetch configuration [{cause}] by CNR in {produce.short.name}
[{SCGMgmtIp}].
Description This event occurs when the CNR receives an error or negative acknowledgment/
improper/incomplete information from the configuration change notifier (CCN).
Incorrect flat file configuration
TABLE 451 Incorrect flat file configuration event
Event Incorrect flat file configuration
Event Type incorrectFlatFileCfg
Event Code 1012
Severity Major
Attribute "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="aut", "realm"="NA",
"SCGMgmtIp"="xxxx", "cause"="xxx”, "file"="xx”
Displayed on the web
interface
[{srcProcess}] detected an configuration parameter is incorrectly configured in file
[{file}] at {produce.short.name} [{SCGMgmtIp}].
Description This event occurs when any flat file configuration parameter is not semantically or
syntactically correct.
Events Types
Configuration Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 241