TABLE 495 DHCP dcln received event (continued)
Event DHCP dcln received
Displayed on the web
interface
DHCP Decline was received by {produce.short.name} [{SCGMgmtIp}] from UE
[{ueMacAddr}]
Description This event occurs when the controller receives the DHCP declined message. The
GTP (GPRS Tunneling Protocol) tunnel is deleted and recreated.
GA Interface Events
NOTE
This section is not applicable for vSZ-H.
Following are the events related to the GA interface (CDRs and GTP').
• Connection to CGF failed on page 257
• CGF keepalive not responded on page 257
• CDR transfer succeeded on page 258
• CDR transfer failed on page 258
• CDR generation failed on page 258
Connection to CGF failed
TABLE 496 Connection to CGF failed event
Event Connection to CGF failed
Event Type cnxnToCgfFailed
Event Code 1610
Severity Major
Attribute "mvnoId"="2" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="cip"
"realm"="NA", "radSrvrIp"="7.7.7.7" "cgfSrvrIp"="40.40.40.40"
"SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Connection with CGF [{cgfSrvrIp}] from RADServerIP [{radSrvrIp}] on
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when channel interface processor (CIP) or GPRS tunneling
protocol prime (GTPP) stack detects a connection loss to the charging gateway
function (CGF server.
Auto Clearance This event triggers the alarm 1610, which is auto cleared by the event code 1613.
CGF keepalive not responded
TABLE 497 CGF keepalive not responded event
Event CGF keepalive not responded
Event Type cgfKeepAliveNotResponded
Event Code 1612
Severity Informational
Events Types
GA Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 257