TABLE 679 ZD AP migrated event (continued)
Event ZD AP migrated
Attribute "apMac"=" C0:C5:20:12:2B:2C ", "serialNumber"="501003003033",
"model"="R700", “firmware”=“3.2.0.0.x”
Displayed on the web
interface
ZD-AP [{apMac}] / [{serialNumber}] model [{model}] has been upgraded with
{produce.short.name} AP firmware version - [{firmware}]
Description This event occurs when a ZoneDirector AP has upgraded its firmware with the
controller AP firmware image.
ZD AP rejected
TABLE 680 ZD AP rejected event
Event ZD AP rejected
Event Type zdAPRejected
Event Code 2003
Severity Warning
Attribute "apMac"=" C0:C5:20:12:2B:2C ", "serialNumber"="501003003033",
"model"="ZF7962"
Displayed on the web
interface
ZD-AP [{apMac}] / [{serialNumber}] model [{model}] is not being upgraded with
{produce.short.name} AP firmware because of ACL setting.
Description This event occurs when the ZoneDirector AP is not upgraded with the controller
AP firmware because of ACL setting.
ZD AP migration failed
TABLE 681 ZD AP migration failed event
Event ZD AP migration failed
Event Type zdAPMigrationFailed
Event Code 2004
Severity Major
Attribute “apMac”=“ C0:C5:20:12:2B:2C “, “serialNumber”=“501003003033”,
“model”=“ZF7962”, “firmware”=“3.0.0.0.0”
Displayed on the web
interface
ZD-AP [{apMac}] / [{serialNumber}] model [{model}] is failed to upgrade with
{produce.short.name} AP firmware version - [{firmware}]
Description This event occurs when the Zone Director AP fails to upgrade with the controller
AP firmware image.
Database error
TABLE 682 Database error event
Event Database error
Event Type cassandraError
Event Code 3001
Severity Major
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, "SCGMgmtIp"="2.2.2.2", reason="reason",
Events Types
System Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
324 Part Number: 800-71565-001 Rev A