TABLE 104 ipmiVoltage alarm (continued)
Alarm ipmiVoltage
Displayed on the web
interface
Baseboard voltage [{status}] on control plane [{nodeMac}]
Description This alarm is triggered due to under/over voltage on the control plane. Baseboard
threshold temperatures are:
• Critical high - 66
0
C
• Non critical high - 61
0
C
• Non critical low - 10
0
C
• Critical low - 5
0
C
Recommended Actions Replace the power supply cord. If it does not work, the motherboard needs
replacement.
ipmiThempBB
TABLE 105 ipmiThempBB alarm
Alarm ipmiThempBB
Alarm Type ipmiThempBB
Alarm Code 902
Severity Major
Aggregation Policy From the event code 902 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 927.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Baseboard temperature [{status}] on control plane [{nodeMac}]
Description This alarm is triggered due to the increase/decrease of the baseboard
temperature status of the control plane. Baseboard threshold temperatures are in
the range of 10
0
Celsius to 61
0
Celsius. The default threshold is 61
0
C.
Recommended Actions Check the fan module. Decrease the ambient temperature if the fan module is
working.
ipmiThempFP
TABLE 106 ipmiThempFP alarm
Alarm ipmiThempFP
Alarm Type ipmiThempFP
Alarm Code 903
Severity Major
Aggregation Policy From the event code 903 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 928.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Front panel temperature [{status}] on control plane [{nodeMac}]
Alarm Types
IPMI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 109

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals