TABLE 178 Accounting session interim failed event (continued)
Event Accounting session interim failed
Attribute "mvnoId"=12 "wlanId"=1,"zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345","ueMsisdn"="98787"
"cause"="<reason for failure>"
Displayed on the web
interface
No Response received or Error response received for accounting interim request
for UE with IMSI [{ueImsi}] and MSISDN [{ueMsisdn}] at {produce.short.name}
[{SCGMgmtIp}] because [{cause}]
Description This event occurs when the controller receives an error response for the
accounting interim request. This event is applicable for TTG/PDG provided
accounting process is enabled for the session.
Accounting server not reachable
NOTE
This event is not applicable for vSZ-H.
TABLE 179 Accounting server not reachable event
Event Accounting server not reachable
Event Type accSrvrNotReachable
Event Code 1602
Severity Major
Attribute "mvnoId"=”12”, "ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="radiusd", "realm"="wlan.3gppnetwork.org",
"radProxyIp"="7.7.7.7", "accSrvrIp"="30.30.30.30", "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Accounting Server [{accSrvrIp}] not reachable from Radius Proxy [{radProxyIp}] on
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the controller is unable to connect to either the primary or
secondary accounting server.
Accounting failed over to secondary
NOTE
This event is not applicable for vSZ-H.
TABLE 180 Accounting failed over to secondary event
Event Accounting failed over to secondary
Event Type accFailedOverToSecondary
Event Code 1653
Severity Major
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“primary"=”20.20.20.20” “secondary”=”30.30.30.30” "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Radius Server Failed Over from Primary [{primary}] to Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the secondary accounting RADIUS server is available
after the primary server becomes zombie or dead.
Events Types
Accounting Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 145

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals