EasyManuals Logo

Ruckus Wireless Virtual SmartZone High Scale User Manual

Ruckus Wireless Virtual SmartZone High Scale
341 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #146 background imageLoading...
Page #146 background image
Accounting fallback to primary
NOTE
This event is not applicable for vSZ-H.
TABLE 181 Accounting fallback to primary event
Event Accounting fallback to primary
Event Type accFallbackToPrimary
Event Code 1654
Severity Major
Attribute “mvnoId”=12 “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”radiusd”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radProxyIp”=”7.7.7.7”
“primary"=”20.20.20.20” “secondary”=”30.30.30.30” "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Radius Server Fallback to Primary [{primary}] from Secondary [{secondary}] on
Radius Proxy [{radProxyIp}] on {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the automatic fallback is enabled. The accounting failover
to secondary server has occurred, the revival timer for primary server has expired
and the requests falls back to the primary server.
AP accounting message mandatory parameter missing
NOTE
This event is not applicable for vSZ-H.
TABLE 182 AP accounting message mandatory parameter missing event
Event AP accounting message mandatory parameter missing
Event Type apAcctMsgMandatoryPrmMissing
Event Code 1901
Severity Critical
Attribute “mvnoId”=”12”,“wlanId”=”1”,“zoneId”=”10”,“ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”,
“srcProcess”=”aut”,"userName" = "hello@world.com" ,"SCGMgmtIp"="2.2.2.2",
“ueMacAddr”=”aa:bb:cc:gg:hh:ii”,
“ueMsisdn”=”98787”,“apIpAddress”=”10.1.4.11”
Displayed on the web
interface
[{srcProcess}] Mandatory attribute missing in Accounting Packet received from
AP [{apIpAddress}] on {produce.short.name} [{SCGMgmtIp}], with username
[{userName}]
Description This event occurs when the controller fails to the find the mandatory parameter in
the RADIUS accounting message received from the AP. This is a mandatory
parameter for generating the W-AN-CDR.
Unknown realm
NOTE
This event is not applicable for vSZ-H.
TABLE 183 Unknown realm event
Event Unknown realm
Event Type unknownRealmAccounting
Events Types
Accounting Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
146 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals