ipmiThempPS
TABLE 109 ipmiThempPS alarm
Alarm ipmiThempPS
Alarm Type ipmiThempPS
Alarm Code 906
Severity Major
Aggregation Policy From the event code 906 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 931.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Power supply [{id}] temperature [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the control plane’s power supply shows the status as
either an increase/decrease in temperature. Power supply 1 and power supply 2
threshold temperatures are in the range of -20
0
Celsius to 5
0
Celsius. The default
threshold is 5
0
C.
Recommended Actions Replace the power supply cord. If the problem persists, decrease the ambient
temperature.
ipmiThempP
TABLE 110 ipmiThempP alarm
Alarm ipmiThempP
Alarm Type ipmiThempP
Alarm Code 907
Severity Major
Aggregation Policy From the event code 907 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm code is auto cleared with the event code 932.
Attribute "id"="x", "status"="xxxxx", "nodeMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
Processor [{id}] temperature [{status}] on control plane [{nodeMac}]
Description This alarm is triggered when the reading surpasses threshold value is <= 55
0
Celsius. The default threshold is 55
0
C.
Recommended Actions Check and replace the CPU fan module if required. Decrease the ambient
temperature if the fan module is working.
ipmiThempHSBP
TABLE 111 ipmiThempHSBP alarm
Alarm ipmiThempHSBP
Alarm Type ipmiThempHSBP
Alarm Code 908
Severity Major
Alarm Types
IPMI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 111