Process initiated
NOTE
This alarm is not applicable for vSZ-H.
TABLE 158 Process initiated alarm
Alarm Process initiated
Alarm Type processInit
Alarm Code 5001
Severity Major
Aggregation Policy From the event code 5001 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
PMIPv6 process got re-started on {produce.short.name} [{SCGMgmtIp}]
Description This alarm is logged when PMIPv6 process restarts.
Recommended Actions A manual intervention is required. Download the PMIPv6d log file from the
controller to check the cause of error.
PMIPv6 unavailable
NOTE
This alarm is not applicable for vSZ-H.
TABLE 159 PMIPv6 unavailable alarm
Alarm PMIPv6 unavailable
Alarm Type pmipUnavailable
Alarm Code 5002
Severity Critical
Aggregation Policy From the event code 5002 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBfladeMac”=”aa:bb:cc:dd:ee:ff”, "SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
PMIPv6 process is not stable on {produce.short.name} [{SCGMgmtIp}]
Description This alarm is logged when the PMIPv6 process repeatedly restarts and is not
stable.
Recommended Actions Check the PMIPv6d application log and status from the controller web interface.
Memory allocation failed
NOTE
This alarm is not applicable for vSZ-H.
TABLE 160 Memory allocation failed alarm
Alarm Memory allocation failed
Alarm Type unallocatedMemory
Alarm Code 5003
Alarm Types
System Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
134 Part Number: 800-71565-001 Rev A