TABLE 350 3rd party client join event (continued)
Event 3rd party client join
Description This event occurs when a 3rd party client joins the AP zone session on the data
plane.
3rd party client inactivity timeout
NOTE
This event is not applicable for vSZ-H.
TABLE 351 3rd party client inactivity timeout event
Event 3rd party client inactivity timeout
Event Type 3rdPtyClientInactivityTimeout
Event Code 212
Severity Informational
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”, “clientMac”=”xx:xx:xx:xx:xx:xx”,
“clientIP”=”x.x.x.x”, “zoneUUID”=”xxxxxx”, “userId”=”uuid"
Displayed on the web
interface
3rd party client [{clientIP||clientMac}] disconnected from Zone [{zoneName}] on
DP [{dpName&&dpKey}] due to inactivity.
Description This event occurs when 3rd party client disconnects from an AP zone session on
the data plane due to inactivity.
3rd party client authorization
NOTE
This event is not applicable for vSZ-H.
TABLE 352 3rd party client authorization event
Event 3rd party client authorization
Event Type 3rdPtyClientAuthorization
Event Code 213
Severity Informational
Attribute “dpKey”=”xx:xx:xx:xx:xx:xx”, “clientMac”=”xx:xx:xx:xx:xx:xx”,
“clientIP”=”x.x.x.x”, “zoneUUID”=”xxxxxx”, “userId”=”uuid"
Displayed on the web
interface
3rd Party client [{clientIP||clientMac}] of Zone [{zoneName}] on DP
[{{dpName&&dpKey}}] was authorized.
Description This event occurs when 3rd party client on AP zone session is authorized.
3rd party client authorization failure
NOTE
This event is not applicable for vSZ-H.
TABLE 353 3rd party client authorization failure event
Event 3rd party client authorization failure
Event Type 3rdPtyClientAuthorizationFailure
Events Types
Client Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 209

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals