GGSN not reachable
TABLE 502 GGSN not reachable event
Event GGSN not reachable
Event Type ggsnNotReachable
Event Code 1211
Severity Major
Attribute "mvnoId"="12","ctrlBladeMac"="aa:bb:cc:dd:ee:ff",
"srcProcess"="sm","realm"="NA", "gtpcIp"="5.5.5.5", "ggsnIp"="10.10.10.10",
"SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
GGSN [{ggsnIp}] connected to {produce.short.name} (GTPC-IP [{gtpcIp}]) is not
reachable
Description This event occurs when echo request is timed out.
Echo response not received
TABLE 503 Echo response not received event
Event Echo response not received
Event Type echoRspNotRcvd
Event Code 1212
Severity Informational
Attribute "mvnoId"="12", "ctrlBladeMac"="aa:bb:cc:dd:ee:ff", "srcProcess"="sm"
"realm"="NA" "gtpcIp"="5.5.5.5", "ggsnIp"="10.10.10.10",
"SCGMgmtIp"="2.2.2.2”
Displayed on the web
interface
GGSN [{ggsnIp}] did not respond to Echo Request from {produce.short.name}
(GTPC-IP [{gtpcIp}]) is not reachable
Description This event occurs when GPRS protocol control plane does not receive an
acknowledgment for the single echo request.
GGSN not resolved
TABLE 504 GGSN not resolved event
Event GGSN not resolved
Event Type ggsnNotResolved
Event Code 1215
Severity Major
Attribute "mvnoId"="12", "wlanId"="1","zoneId"="10" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff"
"srcProcess"="aut" "realm"="wlan.3gppnetwork.org" "gtpcIp"="5.5.5.5"
"apn"="ruckuswireless.com" "SCGMgmtIp"="2.2.2.2"
"ueMacAddr"="aa:bb:cc:gg:hh:ii" "ueImsi"="12345" "ueMsisdn"="98787"
Displayed on the web
interface
Failed to resolve GGSN from APN [{apn}] for UE with IMSI [{ueImsi}] and MSISDN
[{ueMsisdn}]
Description This even occurs when access point name is unable to resolve to gateway GPRS
support node.
Events Types
Gn/S2a Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
260 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals