TABLE 134 STA response timer expired alarm (continued)
Alarm STA response timer expired
Displayed on the web
interface
[{srcProcess}] Tx timer expired no response received from 3GPP AAA
[{aaaSrvrIp}]
Description This alarm is triggered when transaction timer expires. There is no response from
3GPP AAA server for the request sent by {produce.short.name}.
Recommended Actions The operator should check the interfaces from the controller to 3GPP AAA server.
Alternatively, check if the 3GPP AAA server is down.
Retransmission exhausted
TABLE 135 Retransmission exhausted alarm
Alarm Retransmission exhausted
Alarm Type retransmitExausted
Alarm Code 1560
Severity Major
Aggregation Policy From the event code 1560 an alarm is raised for every event. A single event
triggers a single alarm.
Attribute “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff”, mvnoId”=12, “srcProcess”=”STA”,
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org", “ueImsi”=”12345”,
“ueUsername”=”98787”, "SCGMgmtIp"="2.2.2.2", “aaaSrvrIp”=”1.1.1.1”
Displayed on the web
interface
[{srcProcess}] Retransmission for [{ueImsi}]/[{ueUsername}] on
{produce.short.name} [{SCGMgmtIp}] to 3GPP AAA [{aaaSrvrIp}] failed.
Retransmission of messages to 3GPP
Description This alarm is triggered when retransmission to 3GPP AAA server fails and there is
no response from 3GPP AAA server.
Recommended Actions The operator should check the interfaces from the controller to 3GPP AAA server.
Alternatively, check if the 3GPP AAA server is down.
NOTE
Refer to STA Interface Events on page 299.
System Alarms
Following are the alarms with the system log severity.
NOTE
{produce.short.name} refers to SCG or vSZ-H
No LS responses on page 124
LS authentication failure on page 124
{produce.short.name} failed to connect to LS on page 125
Syslog server unreachable on page 125
CSV export FTP maximum retry on page 126
CSV export disk threshold exceeded on page 126
CSV export disk max capacity reached on page 126
Process restart on page 127
Alarm Types
System Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 123

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals