TABLE 497 CGF keepalive not responded event (continued)
Event CGF keepalive not responded
Attribute "mvnoId"="2" "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="cip"
"realm"="NA","radSrvrIp"="7.7.7.7" "cgfSrvrIp"="40.40.40.40"
"SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
Heartbeat missed between RAD Server [{radSrvrIp}] and CGF Server [{cgfSrvrIp}]
in {produce.short.name} [{SCGMgmtIp}]
Description This event occurs when channel interface processor does not receive an
acknowledgment for a keep alive request.
CDR transfer succeeded
TABLE 498 CDR transfer succeeded event
Event CDR transfer succeeded
Event Type cdrTxfrSuccessful
Event Code 1613
Severity Debug
Attribute "mvnoId"=12 "ctrlBladeMac"="aa:bb:cc:dd:ee:ff" "srcProcess"="cip"
"realm"="wlan.3gppnetwork.org" "radSrvrIp"="7.7.7.7" "cgfSrvrIp"="40.40.40.40"
"SCGMgmtIp"="2.2.2.2"
Displayed on the web
interface
CDR Transfer successful from RAD Server [{radSrvrIp}] to CGF [{cgfSrvrIp}] on
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the call details record is successfully transferred.
CDR transfer failed
TABLE 499 CDR transfer failed event
Event CDR transfer failed
Event Type cdrTxfrFailed
Event Code 1614
Severity Major
Attribute “mvnoId”=”2” “ctrlBladeMac”=”aa:bb:cc:dd:ee:ff” “srcProcess”=”cip”
“realm”= ”wlan.mnc080.mcc405.3gppnetwork.org" “radSrvrIp”=”7.7.7.7”
"cgfSrvrIp"="40.40.40.40" "SCGMgmtIp"="2.2.2.2" “cause”=”<reason for
failure>”
Displayed on the web
interface
CDR Transfer failed from RAD Server [{radSrvrIp}] to CGF [{cgfSrvrIp}] on
{produce.short.name} [{SCGMgmtIp}]
Description This event occurs when the call detail record transfers fails.
CDR generation failed
TABLE 500 CDR generation failed event
Event CDR generation failed
Event Type cdrGenerationFailed
Event Code 1615
Severity Major
Events Types
GA Interface Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
258 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals