TABLE 124 LMA failed over alarm (continued)
Alarm LMA failed over
Description This alarm is logged when the standby LMA transits to an active mode. This
includes the control plane identifier of the newly active LMA.
Recommended Actions Check the LMA server status from the LMA connectivity page.
DHCP connection lost
NOTE
This alarm is not applicable for vSZ-H.
TABLE 125 DHCP connection lost alarm
Alarm DHCP connection lost
Alarm Type lostCnxnToDHCP
Alarm Code 5102
Severity Major
Aggregation Policy From the event code 5102 an alarm is raised for every event. A single event
triggers a single alarm.
Auto Clearance The alarm is auto cleared with the event code 5101.
Attribute “ctrlBladeMac"="aa:bb:cc:dd:ee:ff”, "SCGMgmtIp"="2.2.2.2",
Displayed on the web
interface
PMIPv6 process cannot connect to DHCP server on {produce.short.name}
[{SCGMgmtIp}]
Description This alarm is logged when the transmission control protocol (TCP) connection is
lost or when the control plane fails to complete the configuration procedure.
Recommended Actions Download the PMIPv6d and dynamic host configuration protocol (DHCP) server
logs from the controller to check the error cause.
NOTE
Refer to PMIPv6 Events on page 291.
SCI Alarms
Following are the alarms related to SCI (Small Cell Insight).
• Connect to SCI failure on page 118
• SCI has been disabled on page 119
• SCI and FTP have been disabled on page 119
Connect to SCI failure
TABLE 126 Connect to SCI failure alarm
Alarm Connect to SCI failure
Alarm Type connectToSciFailure
Alarm Code 4003
Severity Major
Alarm Types
SCI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
118 Part Number: 800-71565-001 Rev A