TABLE 126 Connect to SCI failure alarm (continued)
Alarm Connect to SCI failure
Aggregation Policy From the event code xxx an alarm is raised for every event. A single event triggers
a single alarm.
Auto Clearance The alarm is auto cleared with the event code xxx.
Displayed on the web
interface
Try to connect to SCI with all SCI profiles but failure.
Description This alarm occurs when the controller tries connecting to SCI with its profiles but
fails.
Recommended Actions
SCI has been disabled
TABLE 127 SCI has been disabled alarm
Alarm SCI has been disabled
Alarm Type disabledSciDueToUpgrade
Alarm Code 4004
Severity Warning
Aggregation Policy From the event code xxx an alarm is raised for every event. A single event triggers
a single alarm.
Auto Clearance The alarm is auto cleared with the event code xxx.
Displayed on the web
interface
SCI has been disabled due to SZ upgrade, please reconfigure SCI if needed.
Description This alarm occurs when SCI is disabled due to the controller upgrade. This could
require reconfiguration of SCI.
Recommended Actions The controller does not support SCI prior to version 2.3. You would need to
upgrade SCI to 2.3 or above and reconfigure the required information of SCI on
the controller dashboard.
SCI and FTP have been disabled
TABLE 128 SCI and FTP have been disabled alarm
Alarm SCI and FTP have been disabled
Alarm Type disabledSciAndFtpDueToMutuallyExclusive
Alarm Code 4005
Severity Warning
Aggregation Policy From the event code xxx an alarm is raised for every event. A single event triggers
a single alarm.
Auto Clearance The alarm is auto cleared with the event code xxx.
Displayed on the web
interface
SCI and FTP have been disabled. It is recommended to enable SCI instead of
FTP
Description This event occurs when the SCI and FTP are disabled.
Recommended Actions
NOTE
Refer to Events Types on page 141.
Alarm Types
SCI Alarms
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
Part Number: 800-71565-001 Rev A 119

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals